POLLUTANTS
Ethylene/Oxide/Propylene Oxide
Ethylene Oxide (EO) and Propylene Oxide (PO) are utilized as sterilants for medical products
and food products as well as in the manufacture of chemical products such as surfactants.
Although both compounds are readily soluble in water and, in fact, hydrolyze to form ethylene
and propylene glycol the removal of these compounds is not a simple matter.
Both EO and PO are characterized by relatively high vapor pressures in aqueous solution.
Consequently, unless the EO and PO are transformed into other substances in solution, the
scrubbing liquid stream cannot practically be recirculated within the scrubbing system and
still result in effective removal. The alternative, using once-through water for scrubbing,
is not generally practical due to the cost of the water and its treatment. However EO and PO
can be transformed to their respective glycols when hydrolyzed but the hydrolysis reaction is
very slow. Croll-Reynolds’ approach is to make use of the catalyzing effect of acid to increase
the rate of hydrolysis and make a liquid recirculating system workable. The acid of choice is
sulfuric acid in strengths of 5 - 7% by weight.
As shown in the diagram below, a counter current packed tower is used to absorb the EO or PO in
aqueous solution. The liquid exiting the packed tower drains to the "Reactor Tank" which is
designed with sufficient residence time and with certain proprietary internals such that the
liquid discharging from the top of the "Reactor Tank" contains only minute amounts of EO or PO
since conversion to the glycols has taken place.
The liquid stream then flows over to the "Solution Feed Tank" where the flexibility of operating
with varying liquid levels allows for the "swell" of volume as glycol is generated, the discharging
of "spent solution" when the tank’s capacity has been reached, and the addition of fresh sulfuric
acid and water to replace that lost when the "spent solution" is discharged. As a result this system
can operate continuously, if necessary, as discharging of "spent solution" and make-up of fresh
solution is accomplished automatically.
The scrubbing liquid stream leaving the "Solution Feed Tank" is recirculated by a centrifugal
pump, through a heat exchanger for cooling, and back to the packed tower for continual scrubbing.
Croll-Reynolds’ EO and PO scrubbing systems have been designed to provide efficiencies of removal
of in excess of 99.9% when needed. These systems can be supplied in the form of the major components
only all the way to a completely skid mounted, instrumented, and automatically controlled package.